Effective & Reliable

Category: UL PUR Cable

Showing 17–32 of 34 results

  • Placeholder

    UL20968

    Style Number Temperature Rating Voltage Rating Dielectric Strength Spark Test UL20968 60˚C 300V 2000V (AC/1min) 3000V Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: quality polyurethane PUR. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …

    UL20968Read More

    Read more
  • Placeholder

    UL20978

    Style Number Temperature Rating Voltage Rating Dielectric Strength Spark Test UL20978 80˚C 300V 2000V (AC/1min) 3000V Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: quality polyurethane PUR. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …

    UL20978Read More

    Read more
  • Placeholder

    UL20979

    Style Number Temperature Rating Voltage Rating Dielectric Strength Spark Test UL20979 80˚C 600V 2000V (AC/1min) 3000V Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: quality polyurethane PUR. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …

    UL20979Read More

    Read more
  • Placeholder

    UL21029

    Style Number Temperature Rating Voltage Rating Dielectric Strength Spark Test UL21029 60/80˚C 600V 2000V (AC/1min) 3000V Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: quality polyurethane PUR. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …

    UL21029Read More

    Read more
  • Placeholder

    UL21030

    Style Number Temperature Rating Voltage Rating Dielectric Strength Spark Test UL21030 60/80˚C 300V 2000V (AC/1min) 3000V Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: quality polyurethane PUR. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …

    UL21030Read More

    Read more
  • Placeholder

    UL21031

    Style Number Temperature Rating Voltage Rating Dielectric Strength Spark Test UL21031 60/80˚C 125V 2000V (AC/1min) 3000V Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: quality polyurethane PUR. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …

    UL21031Read More

    Read more
  • Placeholder

    UL21032

    Style Number Temperature Rating Voltage Rating Dielectric Strength Spark Test UL21032 60/80˚C 30V 2000V (AC/1min) 3000V Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: quality polyurethane PUR. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …

    UL21032Read More

    Read more
  • Placeholder

    UL21060

    Style Number Temperature Rating Voltage Rating Dielectric Strength Spark Test UL21060 80˚C 600V 2000V (AC/1min) 3000V Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: quality polyurethane PUR. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …

    UL21060Read More

    Read more
  • Placeholder

    UL21127

    Style Number Temperature Rating Voltage Rating Dielectric Strength Spark Test UL21127 60/75˚C 600V 2000V (AC/1min) 3000V Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: quality polyurethane PUR. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …

    UL21127Read More

    Read more
  • Placeholder

    UL21139

    Style Number Temperature Rating Voltage Rating Dielectric Strength Spark Test UL21139 60˚C 300V 2000V (AC/1min) 3000V Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: quality polyurethane PUR. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …

    UL21139Read More

    Read more
  • Placeholder

    UL21140

    Style Number Temperature Rating Voltage Rating Dielectric Strength Spark Test UL21140 60˚C 600/1000V 2000V (AC/1min) 3000V Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: quality polyurethane PUR. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …

    UL21140Read More

    Read more
  • Placeholder

    UL21238

    Style Number Temperature Rating Voltage Rating Dielectric Strength Spark Test UL21238 80˚C 600V 2000V (AC/1min) 3000V Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: quality polyurethane PUR. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …

    UL21238Read More

    Read more
  • Placeholder

    UL21294

    Style Number Temperature Rating Voltage Rating Dielectric Strength Spark Test UL21294 80˚C 600V 2000V (AC/1min) 3000V Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: quality polyurethane PUR. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …

    UL21294Read More

    Read more
  • Placeholder

    UL21314

    Style Number Temperature Rating Voltage Rating Dielectric Strength Spark Test UL21314 60˚C 90V 2000V (AC/1min) 3000V Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: quality polyurethane PUR. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …

    UL21314Read More

    Read more
  • Placeholder

    UL21315

    Style Number Temperature Rating Voltage Rating Dielectric Strength Spark Test UL21315 60˚C 600V 2000V (AC/1min) 3000V Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: quality polyurethane PUR. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …

    UL21315Read More

    Read more
  • Placeholder

    UL21320

    Style Number Temperature Rating Voltage Rating Dielectric Strength Spark Test UL21320 80˚C 1000V 2000V (AC/1min) 3000V Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: quality polyurethane PUR. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …

    UL21320Read More

    Read more