UL22181
Style Number | Temperature Rating | Voltage Rating | Dielectric Strength | Fire Rating |
UL22181 | 80˚C | 30V | 500V (AC/1min) | VW-1 |
Construction Details
Conductor Material: TC – tinned copper.
Insulation: AWM verified material.
Shield: foil shield, braiding, copper strands wrapped, optional as per request.
Outer Jacket: Polyvinyl Chloride PVC.
Technical Parameters
//
Physical Properties
Aging Temperature: 113℃±2℃
Aging Period: 168HR
Tensile Strength after Aging: min 70%
Elongation after Aging: min 65%
Testing Temperature: 121℃±2℃
Testing Period: 1HR (60minutes)
Deformation: ≤50%
Testing Temperature: 121℃±2℃
Testing Period: 1HR (60minutes)
Heat Shock: No Crack
Testing Temperature: -10℃±2℃
Testing Period: 1HR (60minutes)
Cold Bend: No Crack
Bend Radius: 10X cable diameter
Reference Standard
UL Standard: UL758, UL
AWM Compliance: AWM
European Directive: EU Directive 2015/863/EU (RoHS 3), EU Directive 2012/19/EU (WEEE)
APAC Compliance: China RoHS II (GB/T 26572-2011)
Related products
-
UL2661
Read moreStyle Number Temperature Rating Voltage Rating Dielectric Strength Fire Rating UL2661 80/90/105˚C 300V 500V (AC/1min) VW-1 Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: Polyvinyl Chloride PVC. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …
-
UL2547
Read moreStyle Number Temperature Rating Voltage Rating Dielectric Strength Fire Rating UL2547 80˚C 300V 500V (AC/1min) VW-1 Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: Polyvinyl Chloride PVC. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …
-
UL2576
Read moreStyle Number Temperature Rating Voltage Rating Dielectric Strength Fire Rating UL2576 80˚C 150V 500V (AC/1min) VW-1 Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: Polyvinyl Chloride PVC. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …
-
UL2096
Read moreStyle Number Temperature Rating Voltage Rating Dielectric Strength Fire Rating UL2096 80˚C 300V 500V (AC/1min) VW-1 Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: Polyvinyl Chloride PVC. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …