UL21563
Style Number | Temperature Rating | Voltage Rating | Cold Resistant | Dielectric Strength |
UL21563 | 90˚C | 1000V | -40˚C | 2000V/min |
Construction Details
Conductor Material: TC – tinned copper.
Insulation: AWM verified material.
Shield: foil shield, braiding, copper strands wrapped, optional as per request.
Outer Jacket: cross linked polyethylene XL-PE.
Technical Parameters
//
Physical Properties
Aging Temperature: 136℃±2℃
Aging Period: 168HR
Tensile Strength after Aging: min 70%
Elongation after Aging: min 45%
Testing Temperature: 121℃±2℃
Testing Period: 1HR (60minutes)
Deformation: ≤50%
Testing Temperature: 136℃±2℃
Testing Period: 1HR (60minutes)
Heat Shock: No Crack
Testing Temperature: -10℃±2℃
Testing Period: 4HR (240minutes)
Cold Bend: No Crack
Bend Radius: 10X cable diameter
Reference Standard
UL Standard: UL758, UL
AWM Compliance: AWM
European Directive: EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC Compliance: China RoHS II (GB/T 26572-2011)
Related products
-
UL21414
Read moreStyle Number Temperature Rating Voltage Rating Cold Resistant Dielectric Strength UL21414 150˚C 300V -40˚C 2000V/min Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: cross linked polyethylene XL-PE. Technical Parameters // Physical Properties Aging Temperature: 136℃±2℃ Aging Period: 168HR …
-
UL21412
Read moreStyle Number Temperature Rating Voltage Rating Cold Resistant Dielectric Strength UL21412 125˚C 600V -40˚C 2000V/min Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: cross linked polyethylene XL-PE. Technical Parameters // Physical Properties Aging Temperature: 136℃±2℃ Aging Period: 168HR …
-
UL21562
Read moreStyle Number Temperature Rating Voltage Rating Cold Resistant Dielectric Strength UL21562 90˚C 600V -40˚C 2000V/min Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: cross linked polyethylene XL-PE. Technical Parameters // Physical Properties Aging Temperature: 136℃±2℃ Aging Period: 168HR …
-
UL21399
Read moreStyle Number Temperature Rating Voltage Rating Cold Resistant Dielectric Strength UL21399 105˚C 300V -40˚C 2000V/min Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: cross linked polyethylene XL-PE. Technical Parameters // Physical Properties Aging Temperature: 136℃±2℃ Aging Period: 168HR …