Category: Feature Products
Showing all 8 results
-
UL20084
Read moreStyle Number Temperature Rating Voltage Rating Dielectric Strength Spark Test UL20084 60˚C 300V 2000V (AC/1min) 3000V Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: TPU – Thermoplastic polyurethane. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: …
-
UL20197
Read moreStyle Number Temperature Rating Voltage Rating Dielectric Strength Spark Test UL20197 60˚C 30V 2000V (AC/1min) 3000V Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: TPU – Thermoplastic polyurethane. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: …
-
UL20280
Read moreStyle Number Temperature Rating Voltage Rating Dielectric Strength Spark Test UL20280 80˚C 300V 2000V (AC/1min) 3000V Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: TPU – Thermoplastic polyurethane. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: …
-
UL20318
Read moreStyle Number Temperature Rating Voltage Rating Dielectric Strength Spark Test UL20318 60˚C 300V 2000V (AC/1min) 3000V Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: TPU – Thermoplastic polyurethane. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: …
-
UL20410
Read moreStyle Number Temperature Rating Voltage Rating Dielectric Strength Spark Test UL20410 60˚C 300V 2000V (AC/1min) 3000V Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: quality polyurethane PUR. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …
-
UL20411
Read moreStyle Number Temperature Rating Voltage Rating Dielectric Strength Spark Test UL20411 60˚C 150V 2000V (AC/1min) 3000V Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: quality polyurethane PUR. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …
-
UL20567
Read moreStyle Number Temperature Rating Voltage Rating Dielectric Strength Spark Test UL20567 60˚C 30V 2000V (AC/1min) 3000V Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: quality polyurethane PUR. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …
-
UL2516
Read moreStyle Number Temperature Rating Voltage Rating Dielectric Strength Fire Rating UL2516 105˚C 600V 500V (AC/1min) VW-1 Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: Polyvinyl Chloride PVC. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …