Style Number | Temperature Rating | Voltage Rating | Dielectric Strength | Spark Test |
UL20152 | 90˚C | 300V | 2000V (AC/1min) | 3000V |
Construction Details
Conductor Material: TC – tinned copper.
Insulation: AWM verified material.
Shield: foil shield, braiding, copper strands wrapped, optional as per request.
Outer Jacket: quality polyurethane PUR.
Technical Parameters
Core Number |
Size (AWG) |
Strands (No/mm) | Insulation (mm) | Jacket (mm) |
OD Ref. (mm) |
Resistance (Ω/KM) |
2 | 28 | 7/0.127 | 0.23 (0.009″) | 0.76 (0.03″) | 4.11 | 239.00 |
2 | 26 | 7/0.16 | 0.23 (0.009″) | 0.76 (0.03″) | 4.33 | 150.00 |
2 | 24 | 11/0.16 | 0.23 (0.009″) | 0.76 (0.03″) | 4.54 | 94.20 |
2 | 22 | 17/0.16 | 0.23 (0.009″) | 0.76 (0.03″) | 4.97 | 59.40 |
2 | 20 | 21/0.178 | 0.23 (0.009″) | 0.76 (0.03″) | 5.40 | 36.70 |
2 | 18 | 34/0.178 | 0.23 (0.009″) | 0.76 (0.03″) | 5.83 | 23.20 |
2 | 16 | 26/0.254 | 0.23 (0.009″) | 0.76 (0.03″) | 6.70 | 14.60 |
3 | 28 | 7/0.127 | 0.23 (0.009″) | 0.76 (0.03″) | 4.11 | 239.00 |
3 | 26 | 7/0.16 | 0.23 (0.009″) | 0.76 (0.03″) | 4.33 | 150.00 |
3 | 24 | 11/0.16 | 0.23 (0.009″) | 0.76 (0.03″) | 4.54 | 94.20 |
3 | 22 | 17/0.16 | 0.23 (0.009″) | 0.76 (0.03″) | 4.97 | 59.40 |
3 | 20 | 21/0.178 | 0.23 (0.009″) | 0.76 (0.03″) | 5.40 | 36.70 |
3 | 18 | 34/0.178 | 0.23 (0.009″) | 0.76 (0.03″) | 5.83 | 23.20 |
3 | 16 | 26/0.254 | 0.23 (0.009″) | 0.76 (0.03″) | 6.70 | 14.60 |
Physical Properties
Aging Temperature: 113℃±2℃
Aging Period: 168HR
Tensile Strength after Aging: min 70%
Elongation after Aging: min 65%
Testing Temperature: 121℃±1℃
Testing Period: 1HR (60minutes)
Deformation: ≤50%
Testing Temperature: 121℃±1℃
Testing Period: 1HR (60minutes)
Heat Shock: No Crack
Testing Temperature: -10℃±2℃
Testing Period: 1HR (60minutes)
Cold Bend: No Crack
Reference Standard
UL Standard: UL758, UL20152
AWM Compliance: AWM 20152
European Directive: EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC Compliance: China RoHS II (GB/T 26572-2011)
Related products
-
UL20968
Read moreStyle Number Temperature Rating Voltage Rating Dielectric Strength Spark Test UL20968 60˚C 300V 2000V (AC/1min) 3000V Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: quality polyurethane PUR. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …
-
UL20979
Read moreStyle Number Temperature Rating Voltage Rating Dielectric Strength Spark Test UL20979 80˚C 600V 2000V (AC/1min) 3000V Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: quality polyurethane PUR. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …
-
UL21127
Read moreStyle Number Temperature Rating Voltage Rating Dielectric Strength Spark Test UL21127 60/75˚C 600V 2000V (AC/1min) 3000V Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: quality polyurethane PUR. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …
-
UL21060
Read moreStyle Number Temperature Rating Voltage Rating Dielectric Strength Spark Test UL21060 80˚C 600V 2000V (AC/1min) 3000V Construction Details Conductor Material: TC – tinned copper. Insulation: AWM verified material. Shield: foil shield, braiding, copper strands wrapped, optional as per request. Outer Jacket: quality polyurethane PUR. Technical Parameters // Physical Properties Aging Temperature: 113℃±2℃ Aging Period: 168HR …